HJ-80KV CT VT Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer Product Description Purpose The function of the transformer is to reduce the ac ...
HJ-80KV CT VT Testing Equipment High Accuracy 0.01 class 80KV Standard Voltage Transformer Product Description Purpose The function of the transformer is to reduce the ac ... more
Brand Name:RISING
Model Number:HJ-80KV
Place of Origin:China
-
...CT VT Testing Equipment Testing for current transformer equipment: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Testing for Voltage Transformer equipment...
...CT VT Testing Equipment Testing for current transformer equipment: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Testing for Voltage Transformer equipment... more
Brand Name:AI
Model Number:CPT-1
Place of Origin:China
CT VT Testing Equipment Analzer for Current and Voltage Transformer Test
-
CT/PT Ratio & Polarity Tester MCVT-RP01 Technical Index Ratio test range 5A/5A-25000A/5A, 5A/1A-5000A/1A Test object type various CT and all electromagnetic type VT Test accuracy 0.2% Dimension 280*230*100mm Weight 3kGS Features 1) Adopting voltage method...
CT/PT Ratio & Polarity Tester MCVT-RP01 Technical Index Ratio test range 5A/5A-25000A/5A, 5A/1A-5000A/1A Test object type various CT and all electromagnetic type VT Test accuracy 0.2% Dimension 280*230*100mm Weight 3kGS Features 1) Adopting voltage method... more
Brand Name:HNMC
Model Number:MCVT-RP01
Place of Origin:China
0.2 Class CT PT Test Equipment Electromagnetic Type VT
-
... resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for voltage transformer: Turns ratio test Ratio error and
... resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for voltage transformer: Turns ratio test Ratio error and more
Model Number:CPT-III
Place of Origin:China
Certification:ISO9001
CPT-III Fully Automatic CT PT Testing Equipment for CT PT Transformer Testing
-
CT PT Volt-ampere Characteristics Tester , Multifunctional CT PT Testing I. Product Description: With the increase requirement of relay protection, the test and check of v-c characteristic carve and the 10% error carve of instrument transformer have became...
CT PT Volt-ampere Characteristics Tester , Multifunctional CT PT Testing I. Product Description: With the increase requirement of relay protection, the test and check of v-c characteristic carve and the 10% error carve of instrument transformer have became... more
Brand Name:Fanke High-voltage
Model Number:FKFA series
Place of Origin:Wuhan ,China
Multifunctional CT PT Testing Equipment Volt Ampere Tester Easy To Operate
-
...CT PT TESTER FEATURES Steady and transient state characteristic tests of various types of CT/PT The use of advanced power technology, the test knee point reaches up to 40kV No external other auxiliary equipment, stand-alone to complete all test items CT test, easy to test, all the tests are using the same wire connection except the load test It carries with thermal printer, so it can print test...
...CT PT TESTER FEATURES Steady and transient state characteristic tests of various types of CT/PT The use of advanced power technology, the test knee point reaches up to 40kV No external other auxiliary equipment, stand-alone to complete all test items CT test, easy to test, all the tests are using the same wire connection except the load test It carries with thermal printer, so it can print test... more
Brand Name:GFUVE
Model Number:GF106
Place of Origin:China
GF106 CT PT Analyzer Ct Pt Testing Equipment Type Printer Portable Accuracy 0.05%
-
... of CT/PT Analyzer CTP-200P is very high, up to 0.05%. The CT/PT Analyzer can automatically complete the test within seconds by one click of the patented multifunctional rotary mouse. It allows to test the knee-point voltage up to 40kV CTs and PTs on
... of CT/PT Analyzer CTP-200P is very high, up to 0.05%. The CT/PT Analyzer can automatically complete the test within seconds by one click of the patented multifunctional rotary mouse. It allows to test the knee-point voltage up to 40kV CTs and PTs on more
Brand Name:HAOMAI
Model Number:CTP-200P
Place of Origin:China
HAOMAI 10A 230V CT PT Test Equipment Durable High Accuracy 0.05%
-
...testing; Description ● Adopt 9.7 inch touch screen TFT LCD display with clear and beautiful software interface design, user can operate ...
-
ZXHQ-Y Transformer Field Calibrator Product introduction ZXHQ-Y is a Multifunctional Current and Voltage Transformer Characteristic Tester designed in accordance with IEC60044-1 / GB1208, IEC60044-2GB1207, IEC60044-6 / GB16847 and C57.13, the instrument...
-
CT VT Testing Equipment for Current and Voltage Transformer Test Testing for current transformer equipment: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Testing...
CT VT Testing Equipment for Current and Voltage Transformer Test Testing for current transformer equipment: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Testing... more
Brand Name:YUYANG
Model Number:CPT-2
Place of Origin:China
Electrical Current Transformer Testing Equipments With Ac220v ± 10% Power Supply
-
... test during startup conditions. These advanced device health diagnostics even continue during running conditions in order to monitor functions and the hardware of the universal relay. The UR-8NH is a specific type of CT/VT module that may be included in
... test during startup conditions. These advanced device health diagnostics even continue during running conditions in order to monitor functions and the hardware of the universal relay. The UR-8NH is a specific type of CT/VT module that may be included in more
Brand Name:GE Fanuc
Model Number:UR8NH
Place of Origin:USA
GE Fanuc PLC UR8NH Multilin CT/VT Voltage Transformer Relay Module
-
Automatic Portable CT On-Site Transformer Test Equipment for Testing of CT’s Radio/Angle Error in Accuracy Class 0.05 Specifications: Current Mutual-inductor On-site Calibration Device The product is mainly used to test one grade to 0.2S grade field ...
Automatic Portable CT On-Site Transformer Test Equipment for Testing of CT’s Radio/Angle Error in Accuracy Class 0.05 Specifications: Current Mutual-inductor On-site Calibration Device The product is mainly used to test one grade to 0.2S grade field ... more
Brand Name:GENY
Model Number:HN-2K01B2
Place of Origin:China
0.05 Accuracy CT Transformer Testing Automatic Transformer Ratio Tester
-
17.5/24kV Outdoor Three-phsae Epoxy Resin Type Combined CT&VT Description: JLSZXW8-17.5/24.5 “3-phase combined CT&VT” is assembled by 3 set of single-phase combined transformers. 1 set Transformer is composed of 1CT& 1VT. Three-phase star connection, ...
17.5/24kV Outdoor Three-phsae Epoxy Resin Type Combined CT&VT Description: JLSZXW8-17.5/24.5 “3-phase combined CT&VT” is assembled by 3 set of single-phase combined transformers. 1 set Transformer is composed of 1CT& 1VT. Three-phase star connection, ... more
Brand Name:Shenzhen Chuangyin Co., Ltd
Model Number:JLSZXW8-17.5, 24
Place of Origin:China
Epoxy Resin Type Three Phsae Current Transformer Combined CT VT 17.5/22kV
-
...Testing System Automotive Battery Test Equipment EV / PHEV / HEV Battery Testing System CT - 4000 , based on Neware 4th generation testing system , entered into market in 2008 . CT - 4000 supports some testings as follow , EV battery pulse charge / discharge , DCIR - Direct Current Internal Resistance , cycle life and rate . CT...
...Testing System Automotive Battery Test Equipment EV / PHEV / HEV Battery Testing System CT - 4000 , based on Neware 4th generation testing system , entered into market in 2008 . CT - 4000 supports some testings as follow , EV battery pulse charge / discharge , DCIR - Direct Current Internal Resistance , cycle life and rate . CT... more
Brand Name:Neware
Model Number:CTE-6002n-500V200A-IG
Place of Origin:China
Neware 500V200A EV Battery Testing Equipment IP20 Protection Grade
-
CT PT Analyzer HYVA-404 Tests for Current Transformer: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Tests for Voltage Transformer: 1 Turns ratio test...
CT PT Analyzer HYVA-404 Tests for Current Transformer: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Tests for Voltage Transformer: 1 Turns ratio test... more
Brand Name:Huaying
Place of Origin:Wuhan,Hubei,China
Price:email whhy818@163.com
Current Transformer Testing Equipment
-
Product:General Electric UR 8AH GE CT/VT Moudle Fast delivering with good packing Hot sale series: General Electric IC63 / IC695 / IC697 / IC698 / IC200 / ...
-
Brief Introduction Strong weather endurance Transformers Epoxy Resin outdoor CT VT raw material The LW-8224A is a prefilled Bisphenol-A epoxy resin designed for outdoor use in transformers. It is paired with LW-8224B, a ...