Categories | Temperature Test Chambers |
---|---|
Brand Name: | GSKA |
Model Number: | Temperature Humidity Test Chamber |
Certification: | CE SGS ROHS UL |
Place of Origin: | Dongguan China |
MOQ: | 1set |
Price: | Negotiate |
Payment Terms: | T/T, L/C, Western Union, MoneyGram |
Supply Ability: | 100 Set / Sets per Month |
Delivery Time: | 10-60days after confirmed payment or by contract stipulation |
Packaging Details: | Export package |
Cooling Type: | Water Cold |
Controller Resolution: | ±0.3℃;±2.5%RH |
Temperature Variation: | ±2℃ |
Heating Rate: | ≥2.5°C/min |
Cooling Rate: | Average 1.0℃/min, or 15℃/min, |
Applied Standard: | IEC60068 series |
OEM Temp Humidity Chamber Three Element Compound Cold Cycle Ring
put to use:
Reasonable selection of high and low temperature test chamber test
equipment. In order to ensure the normal conduct of the test,
should be according to the different conditions of the test sample,
the selection of appropriate test equipment, test sample and the
effective volume of the test chamber should also maintain a
reasonable ratio. For the test of the heating test sample, the
volume shall not be greater than one tenth of the effective volume
of the test chamber. For non - heating test samples, the volume
should not be greater than one fifth of the effective volume of the
test chamber. For example, a 21 'color TV in the temperature
storage test, choose a cubic volume of the test box can meet the
requirements, and in the power work, it can not meet the
requirements, should change a larger test box, because the TV at
work to diverge heat. In the high and low temperature test chamber
environment test, the required test sample performance, test
conditions/test procedures and test technology to be familiar with,
to be familiar with the technical performance of the test equipment
used to be familiar with, to understand the structure of the
equipment, especially the operation and performance of the
controller to be familiar with. Also carefully read the operation
manual of the test equipment, so as to avoid the abnormal operation
of the test equipment caused by the error of operation, which can
cause the damage of the test sample and the incorrect test data
The main difference:
The difference between high and low temperature test chamber and
high and low temperature alternating test chamber mainly lies in
the control part and the refrigeration part. Control part of the
high and low temperature test chamber is mainly controlled by
digital display instrument, high and low temperature alternating
test chamber is controlled by programmable controller, digital
display instrument for manual control commonly, can follow the
orders for the single, while the programmable controller is
automatic control, can advance to set the number of parameters and
test set in, Then follow the set program. The refrigeration part of
the high and low temperature test chamber is relatively simple, as
long as it can be constant at a certain temperature. And the high
and low temperature alternating test chamber needs to measure a
certain amount of cold, in order to output different amounts of
cold at different temperature points, to achieve alternating. Their
box structure is basically the same, the technical parameters are
the same.
Specification:
Material | Inner material | SUS 304# steel plate | |||
Outside material | SUS 304# steel plate(surface disposing) | ||||
Thermal insulation material | Thermostability high density chlorine formic acid foam insulator | ||||
System wind pathround-robin mode | centrifugal fan-broadband enforce circulation | ||||
Refrigeration way | Single stage compression refrigeration | ||||
Refrigerator | whole sealing piston France Taikang brand Compressor | ||||
Freezing fluid | R4O4A or USA Dupont environmental | ||||
Condensation way | forced air cooling or water-cooling | ||||
Heater | Nichrome heating wire heating | ||||
Humidifier | Semi-enclosed steam humidification | ||||
Water-provide way | full-automatic periodical feeding | ||||
Standard configuration | 1 Observe window(double-deck cavity toughened glass),1 | ||||
Safety device | Non- fuse-switch(compressor overload, refrigerant high low voltage, | ||||
Power | 1φ 220V AC±10% 50/60Hz 3φ 380V AC±10% 50/60Hz |
Constant High Low Temperature Humidity Test Chamber Cabinet
Programmable special for you , any question , please let us