| Categories | Wire Testing Equipment |
|---|---|
| Brand Name: | DAXIAN |
| Model Number: | DX8332A |
| Certification: | CE |
| Place of Origin: | China |
| Standards: | IEC60754‐1 |
| Applicable: | Cable and wire |
| Material: | Fused quartz tube |
| Air flow meter: | 20mL~200mL adjustable |
| MOQ: | 1 set |
| Price: | Negotiable |
| Packaging Details: | Wooden case |
| Delivery Time: | 30 days after order confirmed |
| Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash |
| Supply Ability: | 30 sets per month |
IEC60754‐1 Halogen Acid Gas Release Measurement Tester for Cable
Meets the standards:
It conforms to the standards of GB/T17650.1-1998, GB/T17650.2-1998 and IEC60754‐1:1994, IEC60754‐2:1991; it also satisfies the GB/T19666‐2005 “General Rules for Flame Retardant and Fire-resistant Wire and Cable”. Table 6 regulations and GA306.1-2007 Section 6.3.4, GA306.2-2007 Section 6.3.4, UL2556-2007 Sections 9.10 and 9.11 requirements.
Scope of application:
It is applicable to the determination of the total amount of halogen acid gas in low-halogen and halogen-free flame-retardant cables and the determination of the acidity of gases by measuring PH value and conductivity.
Equipment composition:
First, tube furnace: The effective length of the heating chamber and the diameter of 600 × ф 42mm, equipped with an adjustable electrical heating system. Heating power: 220V /10KW
Second, the combustion tube:
1, material: refractory tube made of silica, corrosion-resistant gas.
2. Specification: The inner diameter is 40mm, the length extending from the inlet side of the tube furnace is 60~200mm, and the length extending from the outlet side is 60~100mm, leaving a space for thermal expansion.
Third, the burning boat:
1, Material: fused quartz tube.
2, specifications: length 100mm, width 25mm, depth 10mm.
3, the combustion boat into the way: the use of bar magnets and platinum wire stroke method.
Fourth, the gas collection: the use of two bottles: one with a magnetic stirrer, and holds 220mL of sodium hydroxide solution.
V. Gas Supply System:
1,Air flow meter: 20mL~200mL adjustable
2. Compressor (provided by your company)
Sixth, sampling: 500mg~1000mg
Seven, the determination of halogen acid content:
1. Analytical balance: the accuracy is 0.1mg
2. Digital PH meter: accuracy is 0.02PH
3, conductivity meter: Measuring range: (0 ~ 1 × 105) μS/cm
|
China Helmet Flame Retardant Performance Testing Equipment For Testing The Flame Retardant Performance Of Safety Helmet wholesale
China Vicat Softening Point Temperature Testing Equipment Microcontroller for Polymer Materials wholesale
China Rubber Testing Equipments For Oxygen Bomb Aging Testing IEC 60811 4000CM3 wholesale