Home > Analyzers >

Low-Energy Pendulum Impact Tester IEC 60898 for Circuit Breaker & Socket Test

Categories MCB Testing Machine
Brand Name: Sinuo
Model Number: SN2507
Certification: Calibration Certificate (Cost Additional)
Place of Origin: China
MOQ: 1
Price: Customized
Payment Terms: T/T
Supply Ability: 10 set per month
Delivery Time: 30 Days
Packaging Details: Plywood Case
Applied Standard: IEC60898-1
Impact Mass: 150±1g(200g)
Mounting Bracket Mass: 10±1Kg
Mounting Bracket Size: 175*175*8 mm
Sample Range: Panel/rail/recessed/panel mount type
Impact Head: R10 polyamide, hardness HR100
Mounting brackets: Can rotate ±90°
Position regulation: 100~100mm adjustable
  • Product Details
  • Company Profile

Low-Energy Pendulum Impact Tester IEC 60898 for Circuit Breaker & Socket Test

Low-Energy Pendulum Impact Tester IEC 60898 for Circuit Breaker & Socket Test


Product Overview:


This Low-Energy Pendulum Impact Test Equipment is designed to perform mechanical impact resistance tests in compliance with IEC 61009-1:2012 and IEC 60898-1:2015 standards. It is applicable to switch sockets, panel-mounted and rail-mounted circuit breakers, contactors, installation boxes, and other electrical devices that may be subjected to mechanical stress during normal use.

Using a 1-meter pendulum principle (test Eha), the impact hammer is released from a defined height, delivering a precise impact to the test sample through gravitational energy conversion. This simulates real-world mechanical shocks to assess the durability and structural safety of exposed parts.


Key Features:


Standard Compliance: IEC 61009-1:2012, IEC 60898-1:2015
No Installation Required: Floor-standing design, ready to use
Flexible Mounting Bracket: Fully adjustable in X, Y, Z directions (±100 mm), and capable of ±90° rotation around both horizontal and vertical axes
Targeted Impact Testing: Release angle can be adjusted to hit front or side surfaces of the sample
Versatile Sample Support: Compatible with panel mount, rail mount, and recessed mount circuit breakers


Technical parameters:


ModelSN2507
Applicable Sample RangePanel mount, rail mount, recessed, panel mount circuit breaker
Impact element headR10 polyamide, hardness HR100
Impact element mass (equivalent mass)150±1g(200g)
Mounting Bracket quality10±1Kg
Mounting bracketsCan rotate ±90° around the mounting plate, the mounting plate can rotate ±90° around the vertical axis, X, Y, Z three axes can be adjusted
Position regulationBracket X-100~100mm, Y-100~100mm, Z-100~100mm stroke adjustable
Swing pendulumA steel pendulum with a length of 1000±1mm, a mass of 100±1g, a material outer diameter of 9 mm, and a wall thickness of 0.5 mm
Impact height0-500mm, scale display (corresponding angle conversion)
Circuit breaker mounting plate175*175*8 laminated board
Specimen fixture

Non-enclosed circuit breaker mounting fixture

Panel mount circuit breaker mounting clamps

Dimension860mm×650mm×2000mm
WeightAbout 140 KG
Height of Fall:
Energy /J0.140.2(0.3)0.35(0.4)0.50.7125102050
Equivalent Mass /kg0.25(0.2)0.25(0.2)0.25(0.2)(0.2)0.250.250.250.51.75510
Height of Fall ±1%mm56(100)80(150)140(200)(250)200280400400300200400500
Note 1, see note 3.2.2; Note 2, the energy unit of this part of the joule (J) is derived from the standard gravity acceleration (g), the whole value of g round: 10m / s2.



Quality Low-Energy Pendulum Impact Tester IEC 60898 for Circuit Breaker & Socket Test for sale
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
Contact Us Quickly