Home > Optical Instruments >

YTC YT-200 YT-220 High Quality SERIES AIR FILTER REGULATOR YT-220BN210 YT-220BN211 Filter Pressure Reducing Valve

Categories Pneumatic Valve Positioner
Brand Name: YTC
Model Number: YT-220BN210
Certification: -
Place of Origin: Korea
MOQ: 1
Price: USD100/PC
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1000
Delivery Time: 1week
Packaging Details: Original
type: fluid Regulators
Weight: 0.6kg (1.7lb)
Min. Filtering Size: 5 micron
Ambient Temperature: Standard Temp. :-20~70℃
Air Connection: PT(NPT) 1/4
  • Product Details
  • Company Profile

YTC YT-200 YT-220 High Quality SERIES AIR FILTER REGULATOR YT-220BN210 YT-220BN211 Filter Pressure Reducing Valve

Product Specification Model YT-200 YT-220 YT-205 YT-225 Max Supply Pressure 1.7 MPa (17 bar) Max Out Pressure 0.42 MPa (A Type) ; 0.84 MPa (B Type) Air Connection PT(NPT) 1/4 PT(NPT) 1/2 Gauge Connection NPT 1/4 PT(NPT) 1/4 PT(NPT) 1/4 NPT 1/2 NPT 1/4 Standard Temp. :-20~70℃ Ambient Temperature NPT 1/4 High Option Temp. : -20~120℃ Low Option Temp: -40~70℃ Min. Filtering Size 5 micron Material Aluminum Diecasting Weight Stainless Steel 316 0.6kg (1.7lb) 0.9kg (1.9lb) 1.4kg (3.0lb) 2.1kg (4.6lb) Tested under ambient temperature of 20’C, absolute pressure of 760mmHg, and humidity of 65%. Please contact Young Tech Co., Ltd for detailed testing specification. 5 YT-200 / 205 / 220 / 225 series 2.6 2.7 2.8 Operation Logic Air pressure is being supplied to the output port as adjust bolt is being turned clock-wise which will push the diaphragm. Pushed down diaphragm will disconnects the disc from the stem. The set pressure level stays by transferring pressure to lower diaphragm, which will result in balancing the adjust spring. In case of higher pressure than set level, the pressure pushes diaphragm and pressure is released through the hole on the spring case. Dimension (YT-200 / 205) Dimension (YT-220 / 225) 6 YT-200 / 205 / 220 / 225 series 3. Installation 3.1 Safety When installing a unit, please ensure to read and follow safety instructions.  Check unit’s specification and ensure to be used as specified.  Ensure the air quality is clean and dry.  Please operate the unit within the specified range of the air pressure level. If exceed, the product can be damaged and may result in result damages and accident.  After the pressure level is adjusted, please make sure that the adjust bolt is completely fastened. 3.2 3.3 YT-200 / 205 / 220 / 225 Installation YT-200 / 205 / 220 / 225 can be installed with or without a bracket depending on the field requirement. Please refer to YT-200 / 205 / 220 / 225 dimensions to make appropriate bracket, if required. Adjustment 1) Before supply main air pressure to the product, please turn the adjusting bolt in counter clockwise, so the ring is not being pushed. 2) Install a pressure gauge on the secondary pressure output port to monitor the pressure level constantly. The pressure gauge indicates the primary pressure that is being output from the product. 3) Block output port and pressure gauge port with ball-valve type or other type of fitting and supply primary pressure to input port. 4) When secondary pressure reaches at the set level, please fasten the adjust bolt. 7 YT-200 / 205 / 220 / 225 series 4. Maintenance 4.1 4.1.1 4.1.2 YT-200 / 205 / 220 / 225 require regular maintenance. Please refer to below repair kit part list. It is suggested to replace all parts at the same time to guarantee the life cycle of the product. Repair kit  Upper diaphragm assembly:  Lower diaphragm: 1 each 1 each Draining condensed water  When draining out condensed water, the main supply pressure to the product must be shut down completely or adjust the pressure level of 1kgf/cm2 or below.  Slowly open drain plug to drain condensed water.  After the draining, please close the drain plug. 4.1.3 Replacing the filter case and parts.  When replacing the filter case or any parts, the main supply pressure to the product must be shut down completely or adjust the pressure level of 1kgf/cm2 or below.  Release the lock nut on the adjust bolt, and rotate the adjust bolt counter-clockwise to lower the setting pressure.  Open drain plug on filter case to drain condensed water and close.  Unscrew the bolts on the filter case in diagonal order.  Replace the filter, o-ring, and stem.  Screw the bolts on the filter case in diagonal order.  Unscrew 6 bolts on the spring case in diagonal order.  Replace the diaphragm assembly.  Screw the bolts on the spring case in diagonal order. Please make sure not to damage the diaphragm when screwing.  After the part replacement, please re-set the air pressure at the desired level. 8 YT-200 / 205 / 220 / 225 series

Quality YTC YT-200 YT-220 High Quality SERIES AIR FILTER REGULATOR YT-220BN210 YT-220BN211 Filter Pressure Reducing Valve for sale
Send your message to this supplier
 
*From:
*To: Mengchuan Instrument Co,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
Company Info
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
Contact Us Quickly