Endress Hauser Condumax CLS19 Analog Conductivity Sensor for Pure Water
![]() |
...Analog conductivity sensor Condumax CLS19 Condumax CLS19 measures conductivity in the low measuring ranges. It performs reliably and accurately in a wide range of applications. Designed for low maintenance and a long operating life, the sensor offers you best value for money. Condumax CLS19 measures conductivity......
SC Automation Limited
|
Endress+Hauser Analog conductivity sensor Condumax CLS19
![]() |
...Analog conductivity sensor Condumax CLS19 Condumax CLS19 measures conductivity in the low measuring ranges. It performs reliably and accurately in a wide range of applications. Designed for low maintenance and a long operating life, the sensor offers you best value for money. Condumax CLS19 measures conductivity......
SC Automation Limited
|
CLS21-C1E4A Analog Conductivity Sensor , Pt100 Condumax CLS21
![]() |
...Analog Conductivity Sensor Condumax CLS21 Measuring Range; Cell Constant: C 0,01-20,0mS/cm; (K=1) Process Connection: 1E Thread G 1"; PES Cable Connection: 4 Plug DIN 4-pole, PG9 Temperature Sensor: A Pt100 Specs at a glance Measurement range k=1: 10,0 µS/cm - 20,0 mS/cm Process temperature max. 135°C (max. 275°F) Process pressure max. 16 bar at 20°С (max. 232psi at 68°F) Field of application Condumax CLS21 is a robust conductivity...
GREAT SYSTEM INDUSTRY CO. LTD
|
CLS16-3D3A1P Analog Conductivity Sensor Condumax CLS16
![]() |
...Analog Conductivity Sensor Condumax CLS16 Process Connection: 3D Clamp ISO2852 1-1/2" Cable Connection: 3 10m fixed cable Temperature Sensor: A Pt100 Additional Option: 1P Basic version Specs at a glance Measurement range k=0,1: 0,04µS/cm - 500µS/cm Process temperature Max. 120°C (150°C/30 min) max. 248°F (302°F/30 min.) Process pressure max. 12 bar at 20°C max.174 psi at 68°F Field of application Condumax......
GREAT SYSTEM INDUSTRY CO. LTD
|
Graphite 2 Electrode Analog Conductivity Sensor With K=1±15% For Waste Water
![]() |
Graphite 2 Electrode Analog Conductivity Sensor With K=1±15% For Waste Water Conductivity analyzers are used to measure electrical conductivity (EC). EC is a widely used analysis parameter for water purity analysis, chemical process control, and industrial......
Suzhou Delfino Environmental Technology Co., Ltd.
|
Indumax CLS54 Endress Hauser CLS54-ASMS012 Analog Conductivity Sensor with SPK CFB and Pt1000 Temperature Sensor
![]() |
...Analog conductivity sensor Indumax CLS54 Field of application The Indumax CLS54 inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products. Indumax CLS54 measures toroidal conductivity......
Achievers Automation Limited
|
5000μS/Cm NPT3/4 316L 2 Electrode Conductivity Sensor Analog Conductivity Meter
![]() |
... Range: 0~80℃ Pressure Rating: 0~2.0MPa Temperature Sensor: NTC10K/NTC2.2K/PT100/PT1000 Installation Interface: Upper NPT3/4, down NPT3/4 Electrode Cable: Standard 10m >>Principle Since ......
Nanjing Juge Environmental Technology Co., Ltd.
|
LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime
![]() |
Product characteristics Number of inputs and outputs Number of analog outputs: 1 Process connection G 1/2 external thread Application System gold-plated contacts Media Conductive liquids Note on media water milk CIP liquids Cannot be used for See the ......
Xiamen ZhiCheng Automation Technology Co., Ltd
|
Multi Parameter Water Quality Monitoring Sensor IP55 Protection
![]() |
...a turbidity sensor...4 sensors can be connected at the same time, at the same time there are analog, digital, switch and other output interfaces. Sensor output RS485 signal, now The anti-interferenceability is stronger when the field is applied. Table 1-1...
Xi'an Kacise Optronics Co.,Ltd.
|
ST Vactrol LCR-0202 Cross 4Pins Dip Photo Conductive Analog Linear Optocoupler WDYJ-0202 With Forward Voltage 2.5V
![]() |
ST Vactrol LCR-0202 Cross 4Pins Dip Photo Conductive Analog Linear Optocoupler WDYJ-0202 With Forward Voltage 2.5V Structure Diagram (Unit:mm Tolerance: ±0.1) Electrical Optical Characteristics Ta=25℃ LED Parameter Symbol Test Conditions Min. Typ. Max. ......